MIL-DTL-0045585E (AR)
4.4 Conformance inspection.
4.4.1 Inspection lot formation. Lot formation shall be in accordance with MIL-
STD-1916. In addition inspection lots shall not exceed 500,000 links per lot. Each
inspection lot shall contain:
a. Coupling from one interfix number from one manufacturer
b. Loops from more than one (1) heat treat batch provided each batch has
successfully passed the inspections specified in paragraph 4.4.2.2, 4.4.2.3, and
4.5.3.
4.4.1.1 Heat treat batch. The heat treat batch shall consist of loops heat treated in
a batch type furnace at one charge or in a continuous type furnace during an
uninterrupted period extending over not more than one eight hour shift.
4.4.2 Classification of characteristics.
a. Sampling requirements. Inspection sampling requirements for Critical, Major
and Minor characteristics are defined in MIL-STD-1916. Unless specified otherwise,
Verification Level IV shall be used for all characteristics defined as Majors and
Verification Level II for all Minor characteristics; Critical characteristics shall be
addressed in accordance with MIL-STD-1916.
b. Conformance inspection. Conformance inspection shall be performed in
accordance with paragraph 4.4.2.1 through 4.4.2.3. For all conformance inspections the
same sample specimen may be used for all non-destructive examinations or tests.