MIL-DTL-0045585E (AR)
Name
Drawing
Quantity
Coupling, Cartridge Link
11691394
25
Loop, Cartridge Link
11691395
100
Link M16A2
11691393
1500
4.3.2 Inspections to be performed. The first article inspection shall be 100%
examination for defects of all drawing characteristics (listed and unlisted) including
workmanship requirements for the parts and assemblies listed in 4.3.1 and the tests
specified in Table II herein.
4.3.3 First article rejection. If any assembly, component or test specimen fails to
comply with any of the applicable requirements, the first article sample shall be rejected.
The Government reserves the right to terminate inspection upon any failure of an
assembly, component or test specimen to comply with any of the requirements.