MIL-DTL-0045585E (AR)
Conformance Inspection
CLASSIFICATION OF CHARACTERISTICS
PARAGRAPH
TITLE
DRAWING NUMBER
11691395
3
3
SHEET
OF
NEXT HIGHER
4.4.2.2
Loop, Cartridge Link (con't)
ASSEMBLY
11691393
REQUIREMENT
INSPECTION METHOD
CONFORMANCE
CLASSIFICATION
EXAMINATION OR TEST
CRITERIA 1/
PARAGRAPH
REFERENCE
202.
Height, pivot slot coupling
Level II
3.2
Gage/
8440212
11017979
203.
True position of top and bottom
Level II
3.2
Gage/
guides
8440213
11017978
204.
Marking misleading or unidentifiable
Level II
3.2
Visual
205.
Evidence of poor workmanship
Level II
3.4
Visual/4.5.18
Notes:
1/. Sample except for Major 118 and 119 shall be selected from each heat treat batch.
2/. Sampling and rejection shall be in accordance with MIL-DTL-16232.
3/. 5 Samples shall be selected from each hour's production from each welding
machine. If any loop fails the weld strength requirement specified on the drawing, the
hour's production represented by the sample per machine shall be rejected.