MIL-DTL-0045585E (AR)
TABLE II. First Article Inspection
CLASSIFICATION OF CHARACTERISTICS
TITLE
DRAWING NUMBER
See Below
1
1
SHEET
OF
Link M16A2 and Components
NUMBER OF
REQUIREMENT
INSPECTION METHOD
EXAMINATION OR TEST
SAMPLE UNITS
PARAGRAPH
REFERENCE
Coupling, Cartridge Link (Dwg. 11691394)
Tensile strength
400
3.2
4.5.1
Salt spray, prior to oil treatment
5
3.2
4.5.2
Loop, Cartridge Link (Dwg. 11691395)
Weld test
10
3.2
4.5.3
Hardness, prior to protective coating
100
3.2
4.5.4
Test for carburization and decarburization,
10
3.2
4.5.5
prior to coating
Salt spray, prior to oil treatment
5
3.2
4.5.2
Link M16A2 (Dwg. 11691393)
Nose fan, butt fan, twist and free hinging
500
3.2
4.5.6, 4.5.7,
test 1/
4.5.8, 4.5.9
Tensile load test 1/
500
3.2
4.5.10
Breakaway force test 2/
500
3.2
4.5.11
Stripping force test 2/
500
3.2
4.5.12
Uncoupling force test 2/
500
3.2
4.5.13
Functioning
500
3.3
4.5.15
Notes:
1/. Fifty (50) belts of ten (10) links each. Same belts shall be used for these tests.
2/. Same links shall be used for these tests.
6