MIL-DTL-0063092B (AR)
Table III. Conformance Inspection.
CLASSIFICATION OF CHARACTERISTICS
DRAWING NUMBER
TITLE
PARAGRAPH
9207989
Case, Cartridge
4.4.2.1
SHEET 1 OF 2
NEXT HIGHER ASSEMBLY
9207988
CLASSIFICATION
EXAMINATION OR TEST
CONFORMANCE
REQUIREMENT
CRITERIA
PARAGRAPH
INSPECTION METHOD
REFERENCE
Critical
Three (3) or more vent holes blocked or
1.
AAIE/4.5.15
3.2
missing
100%
Major
One (1) or two (2) vent holes blocked or
101.
Visual / manual
3.2
missing
100%
Gage/ 4.5.4
3.6
Hardness
Level IV
102.
Concentricity of largest outside
103.
diameter with second largest outside
Gage
3.2
diameter
Level IV
Concentricity of largest inside diameter
104.
Gage
3.2
with second largest outside diameter
Level IV
Concentricity of base plug cavity with
105.
Gage
3.2
second largest outside diameter
Level IV
Concentricity of powder charge cup
106.
Gage
3.2
cavity with base plug cavity
Level IV
Diameter of powder charge cup cavity,
107.
Gage
3.2
min.
Level IV
Gage
Diameter of base plug cavity
3.2
Level IV
108.
Depth from base to bottom of powder
109.
Gage
3.2
charge cup cavity
Level IV
Gage
3.2
Second largest outside diameter 1/
Level IV
110.
Gage
3.2
Level IV
111.
Diameter of node
Gage
3.2
Level IV
112.
Parallelism of open end with base
113.
Perpendicularity of base to second
Gage
3.2
Level IV
largest outside diameter
Gage
3.2
Level IV
114.
Diameter of vent holes
Gage
3.2
Level IV
115.
Largest inside diameter 2/
Gage
3.2
Level IV
116.
Distance of flat of inside projection
Gage
3.2
Level IV
117.
Diameter of flange, max.
Gage
3.2
Level IV
118.
Total length
Visual Equipment
3.2
Level IV
119.
Burr in vent hole
120.
Unconfined second largest outside
Gage
3.2
Level IV
diameter
NOTES:
1/ If the requirements cannot be met in the free state, the go inside diameter plug gage may be inserted in the cartridge
case while inspecting the "go" and "no go" second largest outside diameter. If the "go" inside diameter plug gage is
utilized, the data cards shall be annotated accordingly.
2/ If the requirements cannot be met in the free state, a restricted confining fixture may be utilized while inspecting
the "go" and "no go" largest inside diameter. If the restricted fixture is utilized, the data cards shall be annotate
accordingly.
9
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business