MIL-DTL-0063092B (AR)
Table III. Conformance Inspection.
CLASSIFICATION OF CHARACTERISTICS
DRAWING NUMBER
TITLE
PARAGRAPH
9207988
Cartridge case loading assembly
4.4.2.5
SHEET 1 OF 1
NEXT HIGHER ASSEMBLY
9243909 / 9317510 /
9252411
EXAMINATION OR TEST
CONFORMANCE
CLASSIFICATION
REQUIREMENT
INSPECTION METHOD
CRITERIA
PARAGRAPH
REFERENCE
Critical
Primer above flush with respect to base
1.
100%
of case
AAIE/4.5.15
3.2
Major
Level IV
Base plug above flush
Gage
101.
3.2
Level IV
Depth to base plug, maximum
Gage
102.
3.2
Primer above flush or more than .005
103.
Level IV
below with respect to base plug
Gage
3.2
Level IV
Primer damaged
Visual plus
104.
3.2
magnification 1/
Vent hole blocked or missing
105.
Level IV
(prior to case loading)
3.2
Automatic / Gage
800
Primer function
106.
3.3
4.5.7
2/
Primer deterioration
107.
3.2
4.5.14
Minor
Excessive varnish on exterior surface or
201.
primer
3.2
Visual
Level II
Marking misleading or unidentifiable
3.2
Visual
Level II
202.
Evidence of poor workmanship
Visual/4.5.19
3.9
203.
Level II
NOTES:
1/ Magnification power should not be less than 3 X.
2/ Sampling and rejection shall be in accordance with MIL-P-20444
14