MIL-DTL-0048684B
Conformance Inspection
Classification of Characteristics
PARAGRAPH
TITLE
DRAWING NUMBER
8886327
Cartridge Case Assembly
1
1
SHEET
OF
4.4.2.1
NEXT HIGHER ASSEMBLY
Prior to Loading
9399372
CONFORMANCE
REQUIREMENT
INSPECTION METHOD
CLASSIFICATION
EXAMINATION OR TEST
CRITERIA
PARAGRAPH
REFERENCE
CRITICAL
1.
Closing cup missing
100%
3.2
AAIE/4.5.10
2.
Three (3) or more vent holes blocked
100%
3.2
AAIE/4.5.10
or missing 2/
MAJOR
101.
One (1) or two (2) vent holes blocked
100%
3.2
AAIE/4.5.10
or missing
102.
Two or more closing cups 1/
100%
3.2
AAIE/4.5.10/
Radiography
MINOR
201.
Evidence of poor workmanship
Level II
3.11
Visual/4.5.11
Notes:
1/ May be inspected at higher-level assembly.
2/ Acceptance Inspection of the cartridge case is performed with AIE by the case manufacturer.
Verification at the LAP facility is required.