MIL-DTL-0060944B (AR)
Conformance Inspection
CLASSIFICATION OF CHARACTERISTICS
PARAGRAPH
TITLE
DRAWING NUMBER
4.4.2.5
Cartridge, 40MM, M385A1
8886326
1
1
SHEET
OF
NEXT HIGHER ASSEMBLY
CLASSIFICATION
EXAMINATION OR TEST
CONFORMANCE
REQUIREMENT
INSPECTION METHOD
CRITERIA
PARAGRAPH
REFERENCE
CRITICAL
240 Acc 0
4.5.5
3.2
X-ray examination of ballistic sample
1.
Rej 1
1/
MAJOR
100%
Gage / 9202253
3.2
Chamber gage failure
101.
9202254
9202255
100%
Gage
3.2
Total Length, maximum
102.
240 3/
4.5.5
3.2
X-ray examination of ballistic sample
103.
2/
4.5.6
3.2
104.
Air pressure test
Level III
4.5.7
3.2
105.
Pull test of projectile
Level III
Gage
3.2
106.
Gap, maximum, at rear of rotating band
Level IV
Visual
3.2
107.
Packing exposed
Level IV
108.
Functioning, MK19, MOD III, machine
4.5.8.1
3.4
gun (Single Fire)
144 4/
Functioning, MK19, MOD III, machine
109.
4.5.8.2
3.4
gun (Rapid Fire)
96 4/
MINOR
Visual
3.2
Marking missing, improper or illegible
201.
Level II
Visual / 4.5.11
3.6
Evidence of Poor Workmanship
202.
Level II
NOTES:
1/ A critical defect is defined as a low or high propellant charge or a missing closing cup.
2/ A major defect is defined as any defect not specified in Note 1/.
3/ Any major defect found shall be reported with the exception of two (2) closing cups which shall result in the