MIL-C-50543 (MU)
4.3.2.7 Projectile (See Dwg 0835940 covering a detail of Dwg 8835951).-
Code No.
Method of
Defects
Categories
Inspection
Critical:
None defined
AQL 0.40 Percent
Major
Balance
07001
Weight incorrect
101.
AQL 0.65 Percent
Minor
07002
201.
Evidence of poor workmanship (See 3.10) Visual
4.3,2.8 Cartridge, 40MM, HE, M386 (See Dwg 8835951).-
Code No.
Method of
Defects
Categories
Inspection
Critical:
1. Chamber gage failure (after 5 hr min
cure time at 70°F min in a nose down
08001
Gage
position)
.
Major:
None defined
Minor
AQL 1.50 Percent
201.
Total length
08002
Gage
202.
Visual
Marking missing
08003
203.
08004
Evidence of poor workmanship (See 3.10) Visual
4.3.2.9 Unsealed fiber box (See Dwg 8835105).-
Code No.
Categories
Defects
Method of
Inspection
Critical:
None defined
Major
AQL 0.40 Percent
Visual
101.
09001
Improper number of cartridges
102.
Visual
09002
Separator missing
None defined
Minor:
4.3.2.10 Sealed fiber box, prior to sealing bag (See Dwg 8835105).-
Categories
Defects
Method of
Code No.
Inspection
Critical:
None defined
For Parts Inquires submit RFQ to Parts Hangar, Inc.