MIL-C-50543 (MU)
4.3.2.4 Loading assembly (See Dwg 8840503 covering a detail of Dwg
8835948).-
Categories
Defects
Method of
Code No.
Inspection
Critical:
None defined
Major
AQL 0.40 Percent
101.
Excessive cavitation on bottom of
fuze cavity
Visual
04001
Minor
AQL 0.65 Percent
201.
Evidence of poor workmanship (See 3.10) Visual
04002
4.3.2.5 Projectile, prior to assembling fuze and prior to assembling
sealing compound on fuze threads (See Dwg 8835948 covering a detail of Dwg
8835951).-
Categories
Defects
Method of
Code No.
Inspection
Critical:
None defined
Major
AQL 0.40 Percent
1Q1.
Distance from seating surface on fuze
to end of booster cup, max
Gage
05001
102.
Gap from fuze threads to booster cup,
missing
Visual
05002
Minor:
None defined
4.3.2.6 Projectile, prior to assembling ogive (See Dwg 8835948
covering a detail of Dwg 8835951).-
Categories
Defects
Method of
Code No.
Inspection
Critical:
None defined
Major
AQL 0.40 Percent
101.
Fuze torque failure
06001
Test
102.
Length from curved surface to top
of fuze
Gage
06002
Minor
AQL 0.65 Percent
201.
Evidence of poor workmanship (See 3.10)
Visual
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business