MIL-C-50543 (MU)
Major
100 Percent Inspection
101.
Propellant charge weight obviously
Visual
01004
incorrect (See 6.10)
Minor:
None defined
4.3.2.2 Cartridge case loading assembly, prior to assembling to
projectile (See Dwg 8844609 covering a detail of Dwg 8835951).-
Categories
Method of
Code No.
Defects
Inspection
Critical:
1. Primer above flush with respect to
02001
base of case
Gage
Major
AQL 1.00 Percent
02002
101.
Base plug above flush
Gage
02003
Gage
102.
Depth of base plug, maximum (max)
103.
Primer above flush or more than
.005 below with respect to base
02004
plug
Gage
Visual
02005
104.
Primer damaged
105.
Excessive varnish on exterior
Visual
02006
surface of primer
Minor
AQL 1.00 Percent
02007
201.
Visual
Marking misleading or unidentifiable
02008
202.
Evidence of poor workmanship (See 3.10) Visual
4.3.2.3 Loading assembly, prior to loading (See Dwg 8840503 covering
a detail of Dwg 8835948).-
Code No.
Defects
Method of
Categories
Inspection
None defined
Critical:
Major:
None defined
Minor
AQL 0.65 Percent
201.
Foreign matter on interior surface
03001
(See 3.10)
Visual
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business