MIL-C-50527 (MU)
4.3.2.3 Box, fiber prior to sealing (See Dwg. 9223934).-
Code No.
Method of
Defects
Categories
Inspection
None defined
Critical:
AQL 0.40 Percent
Major:
03001
Visual
Incorrect number of case cartridges
101.
03002
visual
Insufficient fillers
102.
AQL 1.00 Percent
Minor:
03003
Visual
Separator missing
201.
03004
Visual
Case cartridge Inverted
202.
4.3.2.4 Box fiber packing (See Dwg. 9223934 ).-
Code No.
Method of
Defects
Categories
Inspection
04001
Visual
AQL 1.00 Percent
Minor:
04002
Manual
201.
Contents loose
202.
Label or marking missing or
04003
Visual
unidentifiable
4.3.3
Testing
4.3.3.1 Salt spray (See Dwg. 9207989), Major defect, Code
No. 05001.- Four (4) test panels and/or parts shall be selected
from eacn lot and subjected to this test. Rejection shall be as
specified in Specification MIL-A-8625. The test shall be conducted
In accordance with 4.4.1 using equipment in accordance with 4.3.4.
4.3.3.2 Process control Inspection of bath temperature for
anodic coating (See Dwg. 9207989, Major defect, Code No. 06001.-
Continuous monitoring inspection shall be conducted for bath
temperate requirement specified on the applicable drawing. If
the bath temperate for a batch of parts does not comply with the
applicable drawing requirement, the batch shall he suitably identif
classified defective and removed from the lot.