MIL-C-60983C (PA)
6.5 Submission of test data. -In addition to the normal
distribution of records, when the cartridges are procured by the
U.S. Army Munitions Command one (1) copy of all ballistic data and
ammunition data cards shall be forwarded to: Commander, Picatinny
Arsenal, Attn: SARPA-QA-A-S.
6.6 Cost of check test. -The Contracting Officer will arrange
for the contractor to be reimbursed for the expense incurred in the
performance of the check test for deterioration of the primer assemblies.
The tests shall be conducted at Government expense without cost to
the contractor who loaded the primer assemblies or to the contractor
assembling the primer assemblies into the cartridge and shall not
constitute a basis for rejection against either contractor except
where deterioration has occurred as a direct result of carelessness
In handling, storage, etc., permitted while the primer assembly lot
was under the jurisdiction of either contractor.
6.7 Standard deviation shall be calculated from the following
formula or other approved formula:
where:
X = each individual value
= Sample arithmetic means
n = sample size
= the sum of the squares of the differences
between the sample mean and each individual value
one less than the sample
n-1=
6.7.1 For a faster and easier method of arriving at the
standard deviation, the following alternate method may be used.
6.8 Premature burst. -A premature burst is considered to have
occurred if the round functions in gun bore or in flight.
25
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business